shandong zhongtaitongze machinery co., LTD.
Phone:0536-6188269
TEL:18265607258(Manager yu)
Website:yinyue5.cn
Address:Shandong zhucheng Michigan east road no. 7800
The performance characteristics of
L hot water circulation water immersion sterilization.
L water sterilization, cooling water can be recycled.
L PLC automatic control, touch screen input instructions.
L warming and cooling control.
L sterilization process automatic storage function.
L sterilization temperature and time record function.
L manual, automatic separation, can operate independently.
L abnormal temperature, pressure, water level alarm.
L electronic temperature deviation correction.
L electronic temperature automatic protection.
L electronic, mechanical dual overpressure protection.
L electronic, mechanical dual safety chain.
L pot each point temperature difference distribution (hot) plus or minus 0.5 ℃.
L to adapt to the processing of packaging: plastic bottles, flexible packaging, vacuum bag, high temperature cooking bags, aluminum foil bag), tin cans, aluminum cans, aluminum foil, etc.
Conventional model is 700 x 900 x1800 1000 l x2200 1200 x3600mm concrete can customize according to customer's requirements
The working process of the
(1) keep filling good product basket into sterilization pot, kettle door closed. Then kettle door by triple safety interlock to ensure safety. In the whole process of sterilization, mechanical and electrical methods such as chain, guarantee the safe operation of the sterilization pot.
(2) preheating: upward jar filled with water, and into the steam, warm up to the required temperature.
(3) : water on the pot pump water into the pot
(4) sterilization: circulation pump will be sterilization cycle in a closed loop system with water, water total immersion sterilization, with steam into the mixer, the circulating water temperature rising, and control the temperature in need. Tank pressure through the pressure valve and exhaust valve adjustment in the ideal range.
5. Recycling: circulation pump will be sterilization water back to the first tank for next batch of food sterilization.
Cool 6: the pot into cold water, sterilization temperature lowering, and have been to a set temperature.
All landowners drainage: cooling water through the drain valve, the pressure inside the boiler through the exhaust valve leakage.
Cool today, after the completion of the pressure inside the boiler through the exhaust valve leakage, air import valve is opened, the pressure in the pot is zero, discharge products