shandong zhongtaitongze machinery co., LTD.
Phone:0536-6188269
TEL:18265607258(Manager yu)
Website:yinyue5.cn
Address:Shandong zhucheng Michigan east road no. 7800
1, high temperature short time sterilization; Adopt double sterilization pot hot water circulation, a kettle in food sterilization after directly to the high temperature water into another kettle, reduce processing water and heat consumption, shortening the sterilization time, improve the working efficiency.
2, save energy, improve production; In the working medium used in the sterilization process can be recycled, saving energy, time and the consumption of manpower and material resources, reduce the production cost. Two tanks as sterilization pot used interchangeably when sterilization, at the same time increased the production.
3, automatic control system; The whole sterilization process by computer PLC control, a one-time, without manual operation. Adopt touch screen control, all the time by the analog sensors and automatic valve control, can be from a single sterilization process switch to multi-stage sterilization process. Pressure and temperature range of digital display, can be applicable to all products of all kinds of model of pressure and temperature in advance made input in the computer program. Computer can store 100 sterilization formula, in order to choose to use.
4, simulated the temperature control system, can be set multi-stage heating mechanism; According to the requirements of different foods on the sterilization conditions, the set of different heating and cooling process at any time, use of multi-stage heating sterilization ways, make food caloric restriction is small, as much as possible to save its color, aroma, taste and make every kind of food can be prepared under the condition the sterilization. Sterilization temperature to plus or minus 0.3 ℃, can avoid the sterilized digester degrees or weak phenomenon.
5, measure F worth function; On each autoclave are configurable F value measuring instrument, change measuring instrument has the function of the measured value, F value software every 3 seconds for a F value is calculated. All sterilization data, including the sterilization conditions, F value, time - temperature curve, time - pressure curve after treated by data processing software to save or print, so that the production management.
Technical parameters:
project |
1000# |
1200# |
1300# |
1500# |
|||||
The length mm |
2400 |
2400 |
3200 |
3600 |
4000 |
3600 |
4500 |
4000 |
5000 |
Chief, mm |
3900 |
4000 |
4800 |
5000 |
5400 |
5200 |
6100 |
6400 |
7400 |
The total width mm |
1500 |
1800 |
1800 |
1800 |
1800 |
1900 |
1900 |
2100 |
2100 |
High total mm |
3100 |
3300 |
3300 |
3300 |
3300 |
3500 |
3500 |
4100 |
4100 |
capacity m3; |
2.2 |
3.2 |
4 |
4.6 |
4.9 |
5.3 |
6.5 |
7.8 |
9.6 |
Food basket |
3 |
3 |
4 |
4 |
5 |
4 |
5 |
4 |
5 |
Gas consumption |
390 |
570 |
710 |
815 |
870 |
940 |
1150 |
1380 |
1700 |
Equipment power |
9 |
14 |
14 |
14 |
14 |
22 |
22 |
31 |
31 |
Design temperature |
145℃ |
||||||||
Test pressure |
0.44Mpa |
||||||||
Design pressure |
0.35Mpa |